Positive Displacement Blower Calculations

Performance calculations for rotary positive displacement blowers require the use of several equations. These equations are presented below in the calculation order that is most logical. Typical equations are provided for both Roots and Sutorbilt.

Slip represents the amount of gas (air) which leaks back through the very small clearances which are present between the impellers and headplate, the impellers and the cylinder and between the impellers. The slip is the RPM (Revolutions per Minute) required to compensate for this leakage.

Application Slip

Where:

Slipcorrected
Slip of the unit at actual operating conditions (RPM)
Slipapplication
Slip of the unit at 1 psi (measured in RPM)
Δ Pa
Differential Pressure in psi
Δ Ps
Standard Pressure rise = 1 psi
Ps
Standard Absolute Pressure in psia
Pa
Actual absolute inlet pressure in psia
Ta
Actual absolute inlet temperature in °R (°F+460)
Ts
Standard absolute inlet temperature in °R, 528°R
Gs
Standard Specific Gravity of air, 1.0
Ga
Actual Specific Gravity of gas

Slipapplication is determined by blanking off the discharge of a blower and rotating the blower at the speed that will generate a 1 psi at the discharge. This is also referred to as 1 psi slip.

Ga is determined by dividing the molecular weight of the desired gas by 28.964 which is the molecular weight of dry air.

Specific Gravity of a Gas

Blower or vacuum pump inlet volume can be calculated with the following equation:

Blower Vloume Calculation

Where:

Qa
Actual Inlet Volume in cfm
cfr
Cubic Feet per Revolution (displacement)
N
Speed of unit in RPM (revolutions per minute)
Slipcorrected
Slip of the unit at actual operating conditions (RPM)

If cfr is not known for a unit, one could estimate it with the following equation:

cfr estimate based on gear diameter and cylinder length

Where:

GD
Gear Diameter in inches
CL
Cylinder Length in inches

This calculation for cfr assumes an 80% involute profile design.

The brake horsepower required to drive the blower is calculated with the following equation:

Brake Horsepower Calculation
Where:

BHP
Brake Horsepower
GHP
Gas Horsepower
FHP
Friction Horsepower

A quick method to calculate Brake Horsepower to get you in the ball park is to use the following equation:

BHP Quick Calculation

Where:

ΔP
Differential Pressure between inlet and discharge in psi
N
Speed of the unit in RPM
0.00474
Represents a constant that includes 7.8% for friction losses

If you want to fine tune your brake horsepower calculation, the Gas Horsepower will be calculated separately from the Friction Horsepower. Gas Horsepower for a conventional rotary positive displacement blower can be calculated with the following equation:

Gas Horsepower_Conventional

The formula that is used for a Whispair© unit (jet – assisted) is:

Gas Horsepower Jet Assist

Fg must be obtained from a graph that has gear tip speed on the x-axis and Fg on the y-axis. This curve is specific for a particular series of units or a specific unit and is typically proprietary for the blower manufacturer.

Friction Horsepower can be calculated using several different strategies. All strategies require a Friction Horsepower provided by the manufacturer. This friction horsepower is typically based on either Friction Horsepower per 1000 RPM or Friction Horsepower at the maximum RPM which in turn can be related to gear tip speed.

Friction Horsepower per 1000 RPM can be defined as follows:

FHP per 1000 RPM

Friction horsepower defined by the maximum friction horsepower at the maximum speed is:

FHP based on Speed

FHP/1000, FHPN, FHPmax, and Nmax are supplied by the manufacturer.

Gear tip speed in fpm (feet per minute)can be calculated with the following equation:

Gear Tip Speed

GD
Gear Diameter in inches
N
Speed of shaft in RPM

We can now calculate temperature rise on the unit. Temperature rise is a critical calculation since the blower has limits on thermal growth. To much temperature rise and the impellers will expand into the headplates causing the unit to seize and possibly causing extensive damage to the unit.

Two formulas can be used. The first formula is only applicable to air and is as follows:

Temperature Rise for Air

The following formula can be used for any gas:

Temperature Rise for any Gas

 

Ta Actual absolute inlet temperature in °R (°F+460)
BHP Brake Horsepower
Ft Temperature rise factor from manufacturers table
k Ratio of specific heats for a gas cp/cv
Pa Actual absolute inlet pressure in psia
Qa Actual Inlet Volume in cfm

Temperature rise exerts a couple additional limitations on rotary positive displacement blowers. Most manufactures impose an average temperature rule as well as a reduction in maximum allowable temperature rise when inlet gas temperatures exceed ambient conditions.

These two rules can be expressed mathematically as follows:

Average Temperature Rule

Two thirds Rule

Tsuction
Inlet Temperature in °F at blower inlet
Tdischarge
Discharge Temperature in °F at blower discharge
ΔTallowable
Revised maximum allowable temperature rise
ΔTmax
Manufacturers maximum allowable temperature rise
Tambient
Ambient Temperature around the blower in °F

If you want a printable version of this article, please click here.



Related Articles

SCFM (Standard CFM) vs. ACFM (Actual CFM)

Calculation Method to convert SCFM (Standard Cubic Feet per Minute) to ACFM (Actual Cubic Feet per Minute). The calculation is based on standard conditions of 68°F, 36% relative humidity (RH) and 14.7 PSIA.

Read More

Overhung Load for Roots Positive Displacement Blowers

Proper V-Drive selection is essential to achieve maximum life for your blower and vacuum pump. Improper sizing or installation of a v-belt drive can shorten the life of the blower or even cause failure. Roots has provided a means to...

Read More