402242_blower-noise-enclosure_main
402242_blower-noise-enclosure_ventilator
402242_blower-noise-enclosure_louvre-outside
402242_blower-noise-enclosure_louvre-panels

This enclosure was built to fit on top of an existing blower package in a plastic recycling plant. Our engineers worked with the customer to design an enclosure that would meet their sound dampening needs while fitting around existing equipment, electrical connections, and piping.

It maintains a small footprint but features a ventilator and filtered louvre to allow the intake of air to flow up and over the blower.

The final dimensions were 60″ x 42″ x 45″ with 14ga Galvanized Skin, 2″ Rockwool Insulation, a Roof Ventilator, and Metal Mesh Intake Filter.

Brent Bridgeman
Project Lead
Brent Bridgeman
Latest Projects

Fluidizing Pressure Packages

When bulk materials are stored in silos, positive displacement blowers are often used to inject air into the bottom of the silo where it will pass up through the material causing it to act more like a fluid that can...
Read More

Steel Dust Conveying Blower Packages

These pressure packages were designed for a large recycling facility that recovers zinc and lead from industrial waste products. Each blower package features a 616 RAM Blower that provides 1120 CFM of airflow to convey the materials through the process.
Read More