Schedule 40 Pipe Data

Use the table to quickly determine the ID (Inner Diameter) and OD (Outer Diameter) of Schedule 40 Steel Pipe.

Nominal Dia (in)Actual ID (in)Actual OD (in)Wt / FootFlange Dia (in)Flange Thickness (in)Bolt Cir Dia (in)No of BoltsBolt Dia (in)Bolt Length (in)
1/80.2690.4050.25
1/40.3640.5400.43
3/80.4930.6750.57
1/20.6220.8400.86
3/40.8241.0501.14
11.0491.3151.684.2500.4383.12540.5001.75
1 1/41.3801.6602.284.6250.5003.50040.5002.00
1 1/21.6101.9002.725.0000.5633.87540.5002.00
22.0672.3753.666.0000.6254.75040.6252.25
2 1/22.4692.8755.807.0000.6885.50040.6252.50
33.0683.5007.587.5000.7506.00040.6252.50
3 1/23.5484.0009.118.5000.8137.00080.6252.75
44.0294.50010.809.0000.9387.50080.6253.00
55.0475.56314.7010.0000.9388.50080.7503.00
66.0656.62519.0011.0001.0009.50080.7503.25
87.9818.62528.6013.5001.12511.75080.7503.50
1010.02010.75040.5016.0001.18814.250120.8753.75
1211.93812.75053.6019.0001.25017.000120.8753.75
1413.12614.00063.3021.0001.37518.750121.0004.25
1615.00016.00082.8023.5001.43821.250161.0004.50
1816.87618.000105.0025.0001.56322.750161.1254.75
2018.81420.000123.0027.5001.68825.000201.1255.00
2422.62624.000171.0032.0001.87529.500201.2505.50
Data is based on Schedule 40 Steel Pipe and 125# Flanges
Bolt length is based on (2) washers, (1) lock washer and (1) nut

Related Documents

Related Articles

Velocity of a Gas through Schedule 40 Pipe

Quickly estimate the velocity of a gas through Schedule 40 Pipe.

Read More