Sutorbilt Legend ® L Series Performance Data

The Sutorbilt® California Legend “L” series was produced from 1990 until approximately 1996 when it was replaced by the Legend P series with enhanced performance capability. Maximum allowable speeds were increased as well maximum allowable differential pressure and vacuum in some cases.

If you have a Sutorbilt Legend “L” series, the data presented in this table are applicable.

Frame Conn Max RPM cfr Slip Max ΔT Shaft Dia Max ΔP Max Vac
2ML 1″ NPT 4164 0.017 500 180 0.625 10 12
2LL 2″ NPT 4164 0.035 450 160 0.625 6 10
3HL 1-1/4″ NPT 3275 0.045 280 200 0.75 13 14
3ML 2″ NPT 3275 0.060 260 180 0.75 10 14
3LL 2-1/2″ NPT 3275 0.104 230 160 0.75 6 10
4HL 1-1/2″ NPT 3050 0.069 255 200 0.875 13 14
4ML 2-1/2″ NPT 3050 0.117 225 180 0.875 10 14
4LL 3″ NPT 3050 0.170 215 160 0.875 7 12
5HL 2-1/2″ NPT 2440 0.140 150 200 1.125 13 15
5ML 4″ NPT 2440 0.210 140 180 1.125 10 15
5LL 4″ NPT 2440 0.350 125 160 1.125 7 12
6HL 3″ NPT 2100 0.227 130 240 1.375 15 16
6ML 5″ NPT 2100 0.383 115 225 1.375 11 16
6LL 6″ FLG 2100 0.718 100 160 1.375 6 12
7HL 4″ NPT 1800 0.367 100 240 1.562 15 16
7ML 6″ FLG 1800 0.733 85 225 1.562 10 16
7LL 8″ FLG 1800 1.200 75 160 1.562 6 12
8HL 4″NPT 1575 0.566 90 240 1.75 15 16
8ML 8″ FLG 1575 1.04 75 225 1.75 10 16
8LL 10″ FLG 1575 1.74 67 160 1.75 6 12