Sutorbilt 3L Blower
The Sutorbilt 3L Positive Displacement Blower is a model in Gardner Denver’s Sutorbilt Legend series. The current series is the “S” series, so new 3L models may be referred to as 3LS blowers. Older series include the 3LR, 3LP, 3LL, 3LF and 3LB blowers.
pdblowers is a distributor and agent for Howden Roots, the largest manufacturer of positive displacement blowers. We offer repair and replacement services for the Sutorbilt 3L blower. Click here to learn more about Sutorbilt 3L blower repair.
The Roots equivalent for a Sutorbilt Legend 3L is typically the Roots URAI 36, although it is always recommended to check your specific performance requirements when selecting a blower. A basic comparison of specs is below; for more information or to buy online, click here for the Roots 36 URAI blower.
Sutorbilt Legend 3L vs Roots URAI 36
Sutorbilt Legend 3L | Roots URAI 36 | |
---|---|---|
Flow Range: | to 350 CFM | to 330 CFM |
Max Δ Pressure: | 7 psi | 7 psi |
Max Δ Vacuum: | 14″ Hg | 15″ Hg |
Maximum RPM: | 3600 | 3600 |
Minimum RPM: | 1091 | 1090 |
Max ΔT: | 160˚F | 225˚F |
Connection: | 2.5″ FPT | 2.5″ FPT |
Shaft Dia.: | 0.75″ | 0.75″ |
Drive End Lubrication: | Grease | Grease |
Gear End Lubrication: | Oil | Oil |
Required Oil for Gear End (Horizontal Unit): | 18 oz | 16 oz |
Required Oil for Gear End (Vertical Unit): | 9 oz | 8.5 oz |
Recommended Oil: | Aeon PD | Roots Synthetic |
Unit Weight: | 132 lb | 102 lb |
Mounting feet: | Universal | Universal |
Configurations: | LHC, RHC, BHC, THC | LHC, RHC, BHC, THC |
*Mounting feet – Universal mounting feet allow the blower to be mounted in a horizontal or vertical position
**Configurations – This refers to the placement of the driveshaft and orientation of the blower. Click here for more information. Note that for Sutorbilt the default configuration is a right hand driveshaft, while Roots has a left hand driveshaft as their default.
Sutorbilt Model Numbers
The current standard 3L configurations are: GABLCRA, GABLDRA, GABLARA, GABLBRA
Current 3L Models | Catalog # |
---|---|
GABLDSA | 3LS-RHC (or 3L RHC) |
GABLCSA | 3LS-LHC (or 3L LHC) |
GABLASA | 3LVS-BHC (or 3LV BHC) |
GABLBSA | 3LVS-THC (or 3LV THC) |
Model numbers consist of 7 characters and will be stamped on a nameplate on the blower. The first four characters will be the same for all of the 3M blower models. The last three characters will indicate the configuration, series and basic options for the specific blower.
Previous standard model numbers may include: GABLARA (3LVR-THC), GABLBRA (3LVR-BHC), GABLCRA (3LR-LHC), GABLDRA (3LR-RHC), GABLAPA (3LVP-THC), GABLBPA (3LVP-BHC), GABLCPA (3LP-LHC), GABLDPA (3LP-RHC), GABLALA (3LVL-THC), GABLBLA (3LVL-BHC), GABLCLA (3LL-LHC), GABLDLA (3LL-RHC), GABLAFA (3LVF-THC), GABLBFA (3LVF-BHC), GABLCFA (3LF-LHC), GABLDFA (3LF-RHC), GABLABA (3LVB-THC), GABLBBA (3LVB-BHC), GABLCBA (3LB-LHC), GABLDBA (3LB-RHC)